DETEX ELECTRONIC

DETEX ELECTRONIC consists of a structure with an electronic card detonator on one end of the communication cable and a communication connector on the other end. It is a system that can control and blast total of 1.000 detonators simultaneously from four different channels. Thanks to precisely adjustable delay time setting feature, the desired delay times can be configured in the range of 0–15.000 ms in 1 ms intervals.

DETEX ELECTRONIC was developed by in-house without any technology transfer and it is produced in the Afyonkarahisar factory of Kırlıoğlu with over 80% domestic production rate completely local software and hardware.

Usage Advantages
It is fully programmable.
DETEX ELECTRONIC keeps security at the highest level in field and blasting operations, owing to its specially configured security card (RFID Card) in electronic detonator applications.
Thanks to its delay and configuration feature, it greatly reduces the vibration that occurs at the time of blasting.
DETEX ELECTRONIC detonators provide ease of application in the field due to their independent polarity feature, while minimizing errors.
The DETEX ELECTRONIC detonator connectors can be used on wet surfaces.
DETEX ELECTRONIC ignition systems have high-resistance protection equipment against over-current, over-voltage, static electricity and electromagnetic waves.
Technical specifications
Main Explosive PETN
Outer Body material Aluminum
Product Cable 0.6 mm copper/single wire, twin, red
Surface Line Cable 1mm copper/stranded, twin, yellow
In-Hole Max. Cable Length 50 m
Cable Tensile Strength 140 N
Shelf Life 24 months
Water Tightness 48 hours under 3 bar pressure
ESD Resistance 10 KV airborne 16 KV with contact in accordance with EN 13763-13
RF resistance Compliant with EN 13763-27
150khz and 80mhz/30V/m
80mhz-1ghz/10V/m
1ghz-2ghz/10V/m
Usage Suggestions
DETEX ELECTRONIC detonators can be used with the system-specific equipments LOGGER, BLASTER slave and BLASTER master.
DETEX ELECTRONIC ignition system must be used by qualified personnel who has a certificate of ignition qualification.
Detonator heads should be kept away from all kinds of impact, friction and force.
Products must be stored in accordance with the specified conditions by the manufacturer and be protected from extremely hot environments such as flames.
Safety Directive
Proper Shipping Name DETONATORS, ELECTRONIC programmable for blasting
UN Number 0030 - 0513
Class 1.1 B - 1.4 S